earticle

논문검색

연구논문

소방공무원의 방화복 착용 후 단계별 운동강도 변화 시 의복 내 온도·습도·발한량 차이

원문정보

The change in temperature·humidity·perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit

최서연, 박일규, 공일천, 이동호

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

The purpose of this study was to verify the change in temperature·humidity·perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit. For this study, three male fire fighters took basic physical test and performed 10 minute phased intensive exercises -exercise intensity I (30%VO2max), exercise intensity II (45%VO2max), exercise intensity III (60%VO2max) based on maximum oxygen consumption (VO2max)- wearing fire suit (helmet, boots, air respirator) in treadmill and took a rest. The result of study shows that the temperature in the suit elevated during stabilization period after each exercise intensity, humidity elevated as exercise intensity increased, perspiration elevated as exercise intensity increased. This study indirectly ascertained the fire suit's physiological change in fire fighters during field activities.

목차

Abstract
 1. 서론
 2. 연구 대상 및 방법
  2.1 연구 기간 및 대상
  2.2 연구 방법
  2.3 통계 방법
 3. 결과
  3.1 운동강도에 따른 활동복과 방화복의 의복 내 온도차이
  3.2 운동강도에 따른 활동복과 방화복의 의복 내 습도 차이
  3.3 운동강도에 따른 활동복과 방화복의 의복 내 발한량 차이
 4. 결론