earticle

논문검색

Comparison of Steady-State Characteristics between DFIG and SCIG in Wind Turbine

초록

영어

Variable speed wind turbine with doubly-fed induction generator (DFIG) is gradually replacing fixed speed one with squirrel cage induction generator (SCIG) in wind power applications. It is worthwhile to compare these two generators with respect to operating principle, controlling ability, etc. This paper concentrates on analyzing active/reactive power relationship in steady-state between DFIG and SCIG by simulation on MATLAB. Another key task investigated in this paper is comparison of electromechanical torque-slip characteristics between DFIG and SCIG with several different conditions such as interconnecting network strength and type, generator terminal voltage, and rotor resistance. Comparison results verify that DFIG has distinct features over SCIG.

목차

Abstract
 1. Introduction
 2. Comparison of Output Power between DFIG and SCIG
  2.1. Equivalent Circuit of DFIG
  2.2. Active Power between DFIG and SCIG
  2.3. Reactive Power between DFIG and SCIG
  2.4. P-Q Relationship between DFIG and SCIG
 3. Electromechanical Torque-slip Characteristics between SCIG andDFIG
  3.1. Strong or Weak Interconnecting Network
  3.2. Interconnecting Network with Overhead Line or Underground Cable
  3.3. Changing the Terminal Voltage
  3.4. Changing the Resistance of Rotor Side
 4. Conclusion
 References

저자정보

  • Phan Dinh Chung Electrical Engineering Department, Danang University of Technology, Vietnam

참고문헌

자료제공 : 네이버학술정보

    ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

    0개의 논문이 장바구니에 담겼습니다.