나선형 홈이 파인 튜브형 EGR Cooler 성능에 대한 수치해석

원문정보

Numerical Analysis on the Performance of EGR Cooler Spiral-grooved tubular

이건화

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In this study, the performance characteristics of EGR Cooler applying to the current commercial vehicle was analyzed by the numerical analysis. Through the experiment the performance evaluation of EGR Cooler must need a lot of time and expenses. On the other hand, the numerical analysis has been used in many research areas as a way to reduce the cost and time. The analysis model of this study has a spiral shape tube. The exhaust gas passes through the inside of the tube. The performance of Cooler was analyzed according to the variation of gas mass flow rate. The results of analysis and experimental was confirmed that was indicating the same trend.

목차

Abstract
 1. 서론
 2. 수치해석 방법
 3. 해석결과 및 고찰
 4. 결론
 참고문헌