earticle

논문검색

제 3 분야 : 건축구조

동조액주관댐퍼(TLCD)를 이용한 고층건물의 공력진동실험

원문정보

Aeroelastic Model Test for a Tall Building using Tuned Liquid Column Damper

유장열, 유기표, 김영문

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

To investigate the effectiveness of a tuned liquid column dampers(TLCD) in suppressing wind-induced excitation motion of a building, aeroelastic wind tunnel tests were conducted. A 1:200 scaled model of an aeroelastic tall building was built, and TLCD models of mass ratio of 1.5%, 3% and 4.5%, respectively, were designed and tested with the building model. As such, in this study, after installing TLCD of various types on the top most floor of aeroelastic model that is similar to the actual structure, centered around the interval where the vortex-induced vibration of low wind speed occurs, by conducting aeroelastic model experiment in suburban areas and attain wind-induced vibrations response, we studied the effects of wind vibration control.

목차

Abstract
 1. 서론
 2. 풍동실험
 3. 공력진동실험
  3.1 짐발장치
  3.2 상사조건 및 실험모형
 4. 실험결과 및 분석
  4.1 변위응답
  4.2 스펙트럼해석
 5. 결론
 감사의 글
 참고문헌

저자정보

  • 유장열 You, Jang-Youl. 전북대학교 대형풍동실험센터 선임연구원, 공학박사, 장경간 철골구조 농촌시설물 연구센터
  • 유기표 You, Ki-pyo. 전북대학교 건축공학과 부교수, 공학박사
  • 김영문 Kim, Young-moon. 전북대학교 건축공학과 교수, 공학박사

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.