원문정보
A study on the Vibration in accordance with the Design Factors of Lightweight Steel Frame Floor
초록
영어
In that cases of Modern buildings, the use of Lightweight steel floors have been increased due to improve the performance of building materials and development the technology of structural analysis. These Lightweight steel floors occur the floor vibration problem because the dynamic load which are affect the people or facility. Through the this background, A study is needed to reduce the floor vibration which cause serious problems on the usability of buildings. The purpose of this paper is to understand the vibration characteristics of actual lightweight steel floor on a variety of Design Factors and to analyze the results by applying the floor vibration evaluation criteria.
목차
1. 서론
2. 바닥진동 평가기준
3. 바닥진동 실험
4. 고유진동수와 감쇠비
5. 바닥진동성능 평가 및 비교
5.1 바닥마감 및 벽체 설치에 따른 바닥진동성능 평가
5.2 실험방법에 따른 바닥진동성능평가
6. 결론
참고문헌