An HTS racetrack-type coil without turn-to-turn insulation was characterized by critical current, sudden discharge, and over-current tests with respect to external pressures applied to the straight sections of the coil. The thermal stability of the non-insulated HTS racetrack-type coil was remarkably enhanced with increasing external pressure applied to the straight sections of racetrack-type coil. Furthermore, over-current test results confirmed that the non-insulated HTS racetrack-type coil with increased turn-to-turn thermal contact has the potential to be manufactured into field coils of HTS wind turbine generators with highly enhanced thermal and electrical stabilities.
목차
1. 서론
2. 실험방법
3. 결과 및 토의
3.1. 임계전류 (lc) 특성
3.2. 급방전 특성
3.3 열폭주 (thermal runaway) 조건
4. 결론