영어

In this paper, we implemented a surveillance system for the power transmission line protection from heavy-duty fender-bender. Laser scanning technology was applied for system design. It was analyzed detailed functions for designed system. Measured detection rate and error rate that are monitoring parameters for both studied system and conventional system were 100%, 0% and 95.8%, 2.1%, respectively. Measurement showed that studied system is almost perfect and better than conventional system. Because this system provides the information to frontline workers with managers of heavy equipments that have possibility of accident, it can be applied to surveillance system for the transmission line protection.

한국어

본 논문에서는 송전선로 중장비 접촉사고 방지를 위한 감시 시스템을 구현하였다. 시스템의 설계는 레이저 스캔기술을 적용하여 설계하였다. 설계한 시스템의 세부적 기능을 분석하였다. 감시 시스템을 구현하여 감시파라미터인 검출율과 오류율을 측정하였으며 기존 감시시스템과 비교하였다. 측정결과 기존대비 검출율은 95.8%에서 100%로 향상되었고, 오류율은 2.1%에서 0%로 개선된 결과를 보였다. 연구한 시스템은 접촉사고에 가능성이 있는 위해 개소의 중장비를 감지하고 현장작업자와 관리자에게 정보를 제공하여 사고를 예방해 주는 시스템이므로 송전선로 접촉사고 방지를 위한 감시시스템에 유용하다.