A Study on Feasibility of UF Backwash by RO Concentrate in UF/RO Wastewater Reuse Process
초록
영어
If ultrafiltration process is used as pre-treatment in the wastewater reuse process, it was possible to apply RO concentrate to UF backwash water, because RO concentrate has low turbidity less than 0.1 nephelometry turbidity unit (NTU). This study was focusing on the reuse of reverse osmosis (RO) concentrate in wastewater reuse process using ultrafiltration (UF) as pre-treatment of RO. In pilot test transmembrane pressure (TMP) increasing rate caused by the use of UF treated water and RO concentrate as UF backwash water was 0.039 and 0.041 bar/day, respectively. No significant difference in operation ability has been found. By using this method, it is expected that the volume of pre-treatment facility and operation cost can be decreased about 8%, and wastewater can also be reduced about 20% compare with using UF permeate to UF backwash water
한국어
하수재이용 공정에 있어서 UF막을 전처리로 사용할 경우 처리수의 탁질은 0.1 비탁법 혼탁도 단위(NTU) 이하로 거의 부유물질이 없는 특징을 지니는 양질의 생산수로 후단 역삼투 공정에서 발생되는 농축수를 UF막의 역세수로 사용이 가능하다. 본 연구는 한외여과(UF) 막을 전처리로 사용하는 하수재이용 공정에서 발생하는 역삼투(RO) 농축수의 재사용 가능여부를 검토하였다. Pilot plant(400 m3/일)를 통한 검증에서 차압(TMP) 상승률은 UF 생산수로 사용하는 방법과 RO농축수를 사용하는 방법이 각각 0.039 bar/일과 0.041 bar/일로 나타나, 운전 성능에 큰 차이가 없음을 확인하였으며, 따라서 RO 농축수를 UF 역세수로 사용하는 것에 대한 적용은 가능한 것으로 판단된다. 본 방법을 이용한다면 UF처리수를 UF역세수로 사용하는 방법과 비교하여 전처리 시설 용량, 운영비 등을 8% 축소할 수 있으며, 폐수발생량 또한 20% 절감이 가능할 것으로 예상된다.