영어

In this paper, we present measurement method of the unknown load impedance. Load impedance is continuously varied by external environment conditions. This arbitrarily varied load impedance can be calculated using 3-point voltage measurement on λ/4 sectioned transmission line. We derived several numerical formulas from 3-point voltage measurement results and drew load impedance selection algorithm from calculated load impedance results. These numerical formulas and load impedance selection algorithm are verified by ADS simulation. Simulation results showed that arbitrary load impedance can be correctly measured using above mentioned formulas and selection algorithm.

한국어

본 논문에서는 물리적인 환경 변화에 의해 발생될 수 있는 갑작스런 부하단 임피던스의 변화를 정확히 측정할 수 있는 방법을 제시하였다. 부하단 임피던스 측정방법으로 λ/4 전송선로(Sectioned Transmission Line) 상에서 측정된 전압을 이용하여 임의의 부하단 임피던스를 구하는 수식을 유도하였고, 계산된 수식의 결과 중 유효한 결과 만을 선택하는 부하단 임피던스 결정 알고리즘을 도출하였다. 제안된 임의의 부하단 임피던스 계산 수식과 부하단 임피던스 결정 알고리즘을 다양한 부하단이 적용된 시뮬레이션을 통해 검증하였고, 시뮬레이션 결과를 통해 임의로 설정한 부하단 임피던스를 정확하게 찾아 주는 것을 확인하였다.

목차

요약
 ABSTRACT
 I. 서론
 Ⅱ. 분할된 λ/4 전송선로 설계
 Ⅲ. 시뮬레이션 및 부하단 임피던스 결정 알고리즘
 Ⅳ. 결론