This study was undertaken to investigation the spray characteristics of the twin fluid atomization nozzle system . The light oil was injected at the normal temperature and injection pressure was 5 bar - 10 bar by 1 bar and volume flow was 0.5, 1.0 and 2,0 mmH2O(X10-2). We measured the SMD of sprayed droplet to study spray characteristics. The following conclusions were reached from the results of these study. 1. The more injection pressure increased, the more SMD decreased. 2. The more measuring distance between pressure nozzle tip and analyser beam increased, the more SMD increased. 3. SMD of the blower-air-added injection system were shown, increasing volume flow decreased respectively. The result of this study indicated the blower-air-added injection system induced beneficial changes in SMD. And it will be considered important indicator for spray characteristics design and performance evaluation of twin fluid atomization nozzle system.
한국어
본 연구는 이유체 분무장치 미립화 장치 분무특성을 연구하기 위해 수행되었다. 실험 조건은 상온에서 분사압력을 5 bar에서 10 bar 까지 1 bar 간격과 송풍기로부터 공기유량은 0.5, 1.0, 2.0 mmH2O(X10-2)로 증가하였으며, 사용된 액체는 경유이다. 분무특성을 연구하기위해 SMD를 측정하였다. 이 실험으로 부터 다음과 같은 결과를 얻었다. 1.분무 압력이 증가할수록 SMD는 점점 감소한다. 2 압력노즐로부터 측정 거리가 증가할수록 SMD도 증가한다. 3 송풍공기가 더해지면서 분무되는 경우의 SMD는 상대적으로 감소하는 것으로 볼 수 있다. 이 연구의 결과로 알 수 있듯이, 송풍공기가 더해지는 분사 장치는 유용한 SMD의 변화를 볼 수 있다. 이는 이유체 분무장치 미립화 장치 분무특성 설계와 성능평가를 위한 중요한 지표로 사용될 수 있을 것으로 판단된다.
목차
Abstract
1. 서론
1.1 연구배경 및 목적
2. 이론적 고찰
2.1 미립화(Atomization)
2.2 분무 입경 평균치
2.3 분무 입경 측정 방법
3. 실험장치 및 방법
3.1 분무유체 공급장치
3.2 분무입경 측정장치 및 방법
3.3 실험 방법
4. 실험 결과 및 고찰
4.1 공기유량변화에 따른 SMD의 변화
4.2 일정한 분무축 거리에서 공기유량과 SMD의 관계
5. 결론