earticle

논문검색

실험논문 (원저논문)

코핑 두께의 차이에 따른 POM 보철물의 변연적합도 연구

원문정보

Comparison of the marginal fit of POM restorations with different thickness of metal copings

임형택

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어


Purpose: The purpose of this in vitro study was to compare the marginal fit of POM restorations with 3 different thickness of metal coping. Methods: 2.0 Occlusal reduction, 1.0mm preparation of axial wall with 6degree taper, and chamfer margin was prepared a maxillary first premolar on dentiform. Duplicate prepared die and, make 30 individual dies with Ni-Cr metal. Make 3 groups of 30 press ceramic on Metal crown with different thickness of metal coping; 10 of 0.1 , 10 of 0.3 , 10 of 0.5 thickness metal coping. The marginal fit of the crowns was evaluated 50 points per 1 crown, around the crown margin circumference under a optical microscope at original magnification 100. A 1-way analysis of variance (ANOVA) was used to compare data. Results: The mean marginal discrepancy for POM with 0.1 metal copings was 72.56 , 67.83 for 0.3 metal coping POMs, and 72.56 for 0.5mm metal coping POM. The 1-way ANOVA showed significant difference among 3 groups. Conclusion: The marginal fit of pressed-on-metal (POMs) was best with 0.3 thickness of metal coping, fallowing by 0.1 , and 0.5 in the order.

목차

[Abstract]
 Ⅰ. 서론
 Ⅱ. 연구 방법
  1. 연구재료
  2. 실험방법
 Ⅲ. 결과
  1. 0.1㎜ 코핑 POM의 평균 변연간격
  2. 0.3㎜ 코핑 POM의 평균 변연간격
  3. 0.5㎜ 코핑 POM의 평균 변연간격
  4. 각 그룹간 차이와 그룹 내 신뢰도 검정
 Ⅳ. 고찰
 Ⅴ. 결론
 참고문헌

저자정보

  • 임형택 Lim, Hyung-tek. 한양대학교병원 치과기공실

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.