earticle

논문검색

생산기술

저에너지주택내 공기열 멀티 히트펌프 시스템의 공간냉방 성능평가

원문정보

Cooling Performance Evaluation of Air Source Heat Pump System in Low Energy House

이철희, 나환선, 이현주, 황성욱

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In the study, space cooling performance of air source heat pump(ASHP) was evaluated in a pilot house. The ASHP, which provide for floor heating, domestic water heating and space cooling/heating, shows cooling capacity of 14.0 kW, when COP of ASHP was 3.21 based on test performance of KS C 9306. Test results shows that cooling capacity was depended on frequency of the compressor. The variable refrigerant flow rate for cooling were supplied into diverse room by using LEV. The COP at setting room temperature of 26℃ was 6.3% higher than the COP at that of 24℃, when the spending time in operation was decreased as 21.2%.

목차

Abstract
 1. 서론
 2. 실증 성능평가 설비 및 방법
  2.1 설치 지역 및 특징
  2.2 멀티형 공기열원 히트펌프 시스템
  2.3 공기열 히트펌프 냉방열량 측정
 3. 결과 및 고찰
  3.1 공기열 히트펌프 냉방열량 측정
  3.2 히트펌프의 냉방모드 사이클 분석
  3.3 실내의 설정온도별 히트펌프 성능 비교
 4. 결론
 참고문헌

저자정보

  • 이철희 C.H. LEE. 한전 전력연구원 녹색성장연구소
  • 나환선 H.S. Nah. 한전 전력연구원 녹색성장연구소
  • 이현주 H.J. Lee. 한전 전력연구원 녹색성장연구소
  • 황성욱 S.W. Hwang. 한전 전력연구원 녹색성장연구소

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.