원문정보
Seismic Retrofit Effectiveness Evaluation of Shear Wall Building Structure with Pilotis Using Buckling-Restrained Brace
초록
영어
In this study, the effectiveness of buckling restrained braces as vibration control device used for improving the seismic performance of a residential building with piloti was examined. The upper structure is shear wall structure resistant to lateral force. And lower structure is moment frame and transfer floor connects the both parts. So large earthquake makes the behavior of the building unstable. The effectiveness of bucking restrained braces on piloti for the seismic retrofit was, which is relatively easy to install and efficient for energy dissipation. In the end, apartment buildings with transfer floor of 5, 10, 15, 20, 25 and 30 stories are selected and the effectiveness of the retrofit were compared based on the actual design drawings. In addition, the effective bracing placements are suggested comparing the retrofit results according to the installation methods of the braces.
한국어
본 연구에서는 필로티를 가지는 주거용 건축물을 대상으로 내진성능 향상을 위한 제진장치로 비좌굴 가새를 적용하여 그 효율성을 검토하였다. 상부에는 벽식구조로 횡력에 저항하고 하부에는 전이층을 두어 모멘트 골조가 되어 약층(weak story)이 형성되므로 대규모지진 발생시 건축물의 불안정 거동을 야기시킨다. 이에 대한 내진보강방안으로 효율적인 에너지 소산 및 설치가 비교적 용이한 비좌굴 가새를 필로티에 설치하여 그 효율성을 검토하였다. 이를 위하여 실제 설계도면을 바탕으로 2층에 전이층을 가지는 아파트를 선정하고, 층수를 5, 10, 15, 20, 25, 30층으로 하여 층수에 따른 적용효과를 비교하였다. 또한 가새의 설치방법에 따른 보강 효과를 검토함으로써 효율적인 가새의 배치방안을 제시하였다.
목차
1. 서론
1.1 연구배경 및 목적
1.2 연구범위 및 방법
2. 수직비정형과 비좌굴 가새
2.1 수직비정형
2.2 비좌굴가새의 구성 및 특징
3. 해석모델
3.1 해석모델
3.2 적용하중
4. 해석결과 분석
4.1 필로티 건축물의 동적거동
4.2 비좌굴 가새의 보강에 따른 거동
4.3 비좌굴 가새의 설치 개소수에 따른 거동
4.4 필로티의 높이에 따른 보강효과
4.5 세대수에 따른 보강효과
5. 결론
참고문헌