earticle

논문검색

저온공학

순간 해석 기법을 이용한 PVT 잔량 측정법의 극저온 균일 온도 조건에서의 실험적 연구

원문정보

Experimental research of Pressure-Volume-Temperature mass gauging method using instantaneous analysis under cryogenic homogeneous condition

서만수, 정상권, 정영석, 구동훈, 지동진

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In the extreme conditions of launch vehicle in a space, such as cryogenic temperature and low-gravity environment, the mass gauging of remaining propellants becomes a difficult problem. Pressure–volume -temperature (PVT) method is one of the attractive mass gauging methods under low-gravity due to its simplicity and reliability. PVT gauging experiment with various mass flow rates of helium injection is carried out with the experimental apparatus creating cryogenic homogeneous condition as the condition of low-gravity. Experimental results are analyzed by a novel PVT gauging analysis method which considers all instantaneous changes of pressure and temperature in the ullage volume with small time intervals. It is observed that the gauging error from the novel PVT gauging analysis is –0.11% with 2 slpm mass flow rate of helium injection.

목차

Abstract
 1. 서론
 2. PVT 잔량 측정법 소개 및 실험 장치
  2.1. PVT 잔량 측정법
  2.2. 실험 장치 및 조건
 3. 기존 PVT 잔량 계측법의 실험 결과
 4. 순간 해석 기법을 적용한 PVT 측정법
 5. 결론
 참고문헌

저자정보

  • 서만수 Mansu Seo. 학생회원, KAIST 기계공학과 통합과정
  • 정상권 Sangkwon Jeong. 정회원, KAIST 기계공학과 교수
  • 정영석 Young-suk Jung. 비회원, 항공우주연구원 선임연구원
  • 구동훈 Donghun Ku. 비회원, KAIST 기계공학과 학부과정
  • 지동진 Dongjin Ji. 비회원, KAIST 부속 한국과학영재고등학교

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.

      • 4,000원

      0개의 논문이 장바구니에 담겼습니다.