AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

초록

영어

The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi‐detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.

목차

Abstract
 1. INTRODUCTION
 2. SUBJECTS AND METHODS
  2.1 Patient Selection and IV Catheter
  2.2 Reproducible Microscopic Magnification Analysis
 3. RESULTS
 4. DISCUSSION
 5. CONCLUSIONS
 REFERENCES

저자정보

  • DAE CHEOL KWEON Department of Radiologic Science, Shin Heung College
  • JONG‐WOONG LEE Department of Radiology, Kyung Hee University Hospital at Gang‐dong, Department of Electronics and Communications Engineering, Gwangwoon University
  • JIWON CHOI Department of Radiological Science, Jeonju University, Department of Physiology, School of Medicine, Chonbuk National University
  • SUNG HWAN YANG Department of Prosthetics and Orthotics, Korean National College of Rehabilitation and Welfare
  • KYUNG‐RAE DONG Department of Radiological Technology, Gwangju Health College University, Department of Nuclear Engineering, Chosun University
  • WOON‐KWAN CHUNG Department of Nuclear Engineering, Chosun University