초록
영어
This paper analyzes the interference effect of ISM(Industrial Scientific Medical) equipment on WLAN in order to protect WLAN in interference environment which WLAN Station is close to ISM equipment. CISPR(International Special Committee on Radio Interference) radiation limit standard was used for interfering power of ISM equipment. Then, MCL(Minimum Coupling Loss) which is for the worst case and MC(Monte Carlo) which is based on statistic interference probability are used to get protection distance. As a result, the protection distance of 105 m was calculated by using MCL for the worst case. And, the protection distance of 17 m was calculated by using MC for statistic analysis.
한국어
본 논문은 MCL(Minimum Coupling Loss)와 MC(Monte-Carlo) 방법을 이용하여 같은 주파수를 사용하는 ISM(Industrial Scientific Medical) 기기와 무선랜이 공간적으로 인접하여 사용될 경우의 간섭 영향 분석을 통해 ISM 기기로부터 무선랜을 보호하기 위한 보호 거리를 제시하였다. CISPR(International Special Committee on Radio Interference)에서 규정한 ISM 기기의 기준치를 간섭 파워로 설정하여 ISM 기기로부터 무선랜을 보호하기 위한 보호 거리를 산출하였다. 그 결과 최악의 상황을 고려한 MCL 분석시 105 m의 보호 거리와 통계적 간섭 확률을 바탕으로 한 MC 분석시 17 m의 보호 거리가 각각 산출되었다.