earticle

논문검색

연구논문

결과분석을 이용한 MEK-PO 제조공장의 폭발사고 사례연구

원문정보

A Case Study of Explosion Accident at MEK-PO Factory using Consequence Analysis

장서일, 신석주, 김태옥

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

In this case study, results of the explosion accident at MEK-PO factory were analysed by using the consequence analysis of quantitative hazard assessment and the explosion energy, the burst pressure of vessel, and overpressures at the explosion center and at 300m distance from the explosion center were estimated, respectively. As a result, we found that a cause of accident was the runaway reaction of product(MEK-PO) because of the molecular expansion in vessel and that the possibility of the runaway reaction was classified the mechanical failure(the obstacle of refrigerator or the shutdown valve), design error, and operating error by lack of thermochemical knowledge. Also, the evasive action to prevent accident was suggested.

목차

Abstract
 1. 서론
 2. 이론적 고찰
  2-1. 폭발영향모델
  2-2. 물리적 폭발모델
  2-3. 비산물 발생모델
 3. 사고사례 분석
  3-1. 사고 개요
  3-2. 사고발생 공정 및 공정조건
  3-3. 사고결과 분석
  3-4. 사고원인 추정
 4. 결론
 5. 참고문헌

저자정보

  • 장서일 Jang Seo Il. 명지대학교 공과대학 화학공학과
  • 신석주 Shin Seok Ju. 명지대학교 공과대학 화학공학과
  • 김태옥 Kim Tae Ok. 명지대학교 공과대학 화학공학과

참고문헌

자료제공 : 네이버학술정보

    ※ 기관로그인 시 무료 이용이 가능합니다.

    • 4,000원

    0개의 논문이 장바구니에 담겼습니다.