Hyporheic zone, where groundwater-stream water mixing occurs, sensitively responds to heat of groundwater and stream water temperature. Variation of stream water temperature has short time period and time dependent, because stream water temperature is influenced by daily fluctuation and seasonal air temperature. On the other hand, groundwater temperature is insignificant. In this study, we conducted 1-dimensional heat transfer analysis. The results show that there are differences of temperature distribution between gaining stream and losing stream with flux in hyporheic zone. Especially, variations of hyporheic water temperature show a significant difference in adjacent streambed, Also, the results shows that distribution of temperature was more affected by groundwater direction than intensity of flux.
한국어
지하수-지표수 혼합구간(Hyporheic zone)은 지표수와 지하수의 온도변화에 민감하게 반응하는 구간이다. 지표수의 경우 대기온도에 영향을 받아 온도의 변화주기가 짧은 반면, 상대적으로 지하수는 온도 변화주기가 길다. 본 연구에서는 지하수-지표수 혼합구간의 유동강도와 방향을 고려하여 깊이별 온도의 수직적 분포특성 분석하였다. 현장자료를 이용한 1차원 열전달 해석 수행결과, 지하수-지표수 혼합구간에서 지하수 유출과 지표수의 유입이 일어나는 지점에서 온도의 분포는 상이한 양상을 보였다. 혼합구간의 수직적 온도 분포의 변화는 하천기저에서 가장 두드러지게 나타났다. 또한 열전달 해석 결과를 바탕으로 연구지 혼합구간의 온도분포는 유동강도보다 유동방향에 지배 받았다.
목차
Abstract
1. 서론
2. 연구지역
3. 연구방법 및 결과
3.1 물질균형방정식
3.2 열전달 해석
3.3 혼합구간의 간극수 유동과 온도
4. 결론