초록

영어

Five assays for anti-HBs were compared to improve potency test of Human lgG preparations. The three commercial EIA kits were optimized including dose response curve ranges and compared by conducting a co-laboratory study. After selecting the most reproducible EIA kit, methods comparison was performed with 22 samples in 5 different days. As a result, EIA (7.7 ± 5.3%) and MEIA (AxSYM: 3.7 ± 1.9%, IMx: 1.6 ± 0.8%) showed precision and accuracy (100.1 ± 12.6%). Therefore, the validated EIA assay was established and it is believed to be comparable to current MEIA.

목차

Abstract
 1. 서론
 2. 재료 및 방법
  2.1. 국제 표준품
  2.2. 국가 표준품
  2.3. 시험검체
  2.4. 국제 · 국가표준품을 이용한 EIA 키트 선정시험
  2.5. 검체를 이용한 시험법 검증 및 공동연구
  2.6. 통계처리
 3. 결과 및 고찰
  3.1. EIA 키트 재현성 비교
  3.2. 표준품별 표준곡선 직선성
  3.3. 희석액별 비교 분석
  3.4. EIA 키트간 상관성 분석
  3.5. EIA 시험법 확립 및 최적 키트의 선정
  3.6. 시험검체를 이용한 EIA 시험법 검증
  3.7. 공동연구를 통한 검체군별 시험법간 · 로트간 · 실험실간검증
 4. 결론