earticle

논문검색

2.3 GHz 대역의 ISM 기기와 WiBro 서비스의 양립성 분석

원문정보

Compatibility between ISM Equipment and WiBro Service at 2.3 GHz band

심용섭, 이일규

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

This paper calculates protection distance to protect WiBro service from ISM(Industrial Scientific Medical) equipment which is used in the same frequency with WiBro. We analyze with a scenario that WiBro receiver is closed to ISM equipment which has interfering power of CISPR(International Special Committee on Radio Interference) 11 limit. As a result, the protection distance of 14 m was calculated by using MCL (Minimum Coupling Loss) for the worst case. And, the protection distance of 10 m was calculated to meet 5 % interference probability below by using MC(Monte Carlo) for statistic analysis in case of a interferer.

한국어

본 논문은 2.3 GHz 대역을 사용하는 ISM(Industrial Scientific Medical) 기기가 동대역을 사용하는 WiBro 서비스에 미치는 간섭 영향을 분석하여 ISM 기기로부터 WiBro 서비스를 보호하기 위한 보호 거리를 산출하였다. 간섭 시나리오로 ISM 기기의 간섭 파워는 CISPR(International Special Committee on Radio Interference) 11의 전계강도 기준치를 적용하였고 WiBro 수신기가 ISM 기기로 근접하는 경우를 구성하여 분석하였다. 그 결과 최악의 상황을 고려한 MCL(Minimum Coupling Loss) 분석시 14 m의 보호 거리와 통계적 간섭 확률을 바탕으로 한 MC(Monte Carlo) 분석시 간섭원의 수가 1개 일 때 간섭 확률 5 %를 만족하기 위해 10 m의 보호 거리가 각각 산출되었다.

목차

요약
 Abstract
 I. 서론
 II. 간섭 시나리오
  1. 간섭원 ISM 기기
  2. 피간섭원 WiBro
  3. 간섭 환경
 III. 간섭 분석 방법
  1. MCL(Minimum Coupling Loss)
  2. MC(Monte Carlo)
 IV. 간섭 분석 결과
  1. MCL을 이용한 보호 거리
  2. MC를 이용한 보호 거리
 V. 결론
 참고문헌

저자정보

  • 심용섭 Yong-Sup Shim. 준회원, 공주대학교/한국전자통신연구원
  • 이일규 II-Kyoo Lee. 정회원, 공주대학교 전기전자제어공학부

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.