영어
Vinyl chloride (VC) and vinylidene chloride (VDC), which may be present in poly(vinyl chloride) (PVC) and poly(vinylidene chloride) (PVDC) food packaging, were analyzed by using a headspace-gas chromatograph (GC)/mass spectrometer (MS) equipped with a PLOT Q column. 1-Chloropropane (1-CP) was used as an internal standard. The determinations of VC and VDC were carried out by monitoring the characteristic ions for each compound: m/z=61, 62, 64 and m/z=61, 96, 98, respectively. The method validated in this study can be suitable for the compliance test of EU regulation. Among 103 food packaging samples, VC and VDC were not detected, except in one PVDC food package. However, the detected level of VDC in the sample was below the EU regulatory specific limitation.
목차
서론
재료 및 방법
표준품 및 시약
분석장비
시료
재질확인
내부표준용액의 조제
표준용액의 조제
GC 컬럼의 선정
질량스펙트럼의 확인 및 선택이온 선정
Headspace 전처리 조건의 확립
검출한계(limit of detection, LOD) 및 정량한계(limit ofquantification, LOQ)
검량선의 작성
회수율
시험용액의 조제
결과 및 고찰
분석대상 시료의 재질확인
칼럼 선정
선택이온 및 크로마토그램
Headspace 전처리 조건의 확립
LOD 및 LOQ
직선성
회수율 및 재현성
시료분석 결과
요약
감사의 글
문헌