earticle

논문검색

Electric Machines and Systems

Electrical Parameter Evaluation of 1 MW HTS Motor via Magnetically Stored Energy Calculation

초록

영어

The superconducting synchronous motor or generator mostly has high permeability iron only around outer yoke portion. Therefore, if excitation voltage (Back E.M.F) is calculated from 2 dimensional magnetic field distributions, it can be largely different from actual value due to additional voltage originated from end coils. In order to calculate the excitation voltage more accurately, 3 dimensional magnetic field calculation is necessary for including the end coil effect from large air-gap structure. The excitation voltage can be calculated by stator (armature) coil linkage flux originated from rotor (field) coil excitation, but it is difficult to calculate the flux linkage exactly because of complicated structure of the stator coil. This paper shows a method to calculate the excitation voltage from 3 dimensional magnetic energy that can be calculated directly from volume integration of magnetic flux density and field intensity scalar product through FEM (Finite Element Method) analysis software.

목차

Abstract
 l. INTRODUCTION
 2. THE ANALYSIS AND TEST MACHlNE
 3. EXCITATION VOLTAGE CALCULATION
  3.1. Excitation Voltage Calculation Procedure through 3D Magnetic Field Analysis
  3.2. Excitation Voltage Calculation of 1 MW HTS Machine through 3D Magnetic Field Analysis
 4. COMPARlSON WITH TEST RESULTS
 5. CONCLUSION
 REFERENCES

저자정보

  • Seung-Kyu Baik Korea Electrolechnology Research lnstitute
  • Young-KiI Kwon Korea Electrolechnology Research lnstitute
  • Ho-Min Kim Korea Electrolechnology Research lnstitute
  • Jae-Deuk Lee Korea Electrolechnology Research lnstitute
  • Yeong-Chun Kim Doosan Heavy Induslries & Construction Co., LTD.,

참고문헌