영어
This study was performed to figure out what would be effective to improve water environment in a retention pond which was located in Incheon. Chemical coagulation, seawater flocculation and Fenton treatment were carried out to improve water and sediment quality for the retention pond. Experimental results showed that pH of 11 was optimum pH for seawater flocculation and the high removal rates in terms of SS and T-P can be obtained by seawater flocculation. To eliminate the pollutants from the sediments we applied Fenton oxidation process. We compared whether direct oxidizing the sediments would be more effective than oxidizing them after elution. By Fenton oxidation only, the COD removal rate was 0.55 grams per one H2O2 gram. Whereas the removed COD grams per one H2O2 gram were 0.69 by Fenton oxidation after elution. It showed that the oxidizing after elution was about 25% more effective than the oxidizing without elution. Both treatments could improve the water quality of a retention pond from a level 6(very bad) to a level 3(normal) of Lake Water Quality Standard.
한국어
본 연구는 인천광역시에 위치한 A 유수지의 효율적인 수환경 개선 방안을 모색하기 위해 수행되었다. 유수지 수질 및 저니질의 개선을 위해서 약품 응집과 해수 응집, 펜턴 처리 실험 등을 수행하였다. 실험 결과 해수응집을 위한 최적 pH는 11이었으며, 해수 응집에 의해 SS, TP 항목 모두 높은 제거효율을 얻을 수 있었다. 저니 토의 오염물질 제거를 위해서는 펜턴 산화 처리를 수행하였다. 저니토를 직접 펜턴 처리하는 경우와 용출 후 펜턴 처리하는 경우에 대한 처리효과를 비교한 결과, 제거-COD/H2O2는 단순 펜턴 처리하는 경우 0.55인 반면 용출 후 펜턴 처리하는 경우 0.69를 나타내어 용출 후에 산화 처리하는 방법이 처리효율 면에서 약 25% 보다 우수한 것으로 나타났다. 이들 두 처리로 유수지 수질을 호소수질기준 Ⅵ등급(매우 나쁨)에서 Ⅲ등급(보통)의 수준으로 개선할 수 있었다.
목차
Abstract
1. 서론
2. 시료 채취 및 분석
3. 결과 및 고찰
3.1 유수지 수질 분석 결과
3.2 응집에 의한 수질 개선 실험
3.3 해수 응집에 의한 수질 개선 실험
3.4 펜턴 산화에 의한 수질 및 저니질 개선 실험
3.5 경제성을 고려한 유수지 수환경 개선 공정
4. 결론
참고문헌