earticle

논문검색

Research Papers

Process Analysis on the Decontamination of Internal Surface of UF6 Cylinder

원문정보

UF6 실린더 내부표면 제염에 관한 공정분석

Kwan Sik Chun, Sung Hyun Yoo, Young June Cho, Jang Pyo Hong, Wook Jin Han, Beong Soon Choi, Pil Sang Kang, Suk Ju Cho

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

To evaluate the efficiency of the decontamination plant for the removal of uranium compounds deposited on the internal surface of UF6 cylinder for its reuse, two demonstration tests of the plant with different ratio of Na2CO3 and H2O2 were carried out, and each test had 5 steps. The main chemical form removed by the tests was to be identified as Na4UO2(CO3)3. More than 50% of uranium was removed by water of the first step, and at the following steps the removal amounts were exponentially decreased. On the other hand, the result shows that the injected amount of Na2CO3 , compared with that of the removed uranium, was stoichiometrically excessed. This suggests that the injected amounts of Na2CO3 , the generation rate of decontaminated waste, and the decontamination steps could be reduced by a process optimization of the plant.

한국어

핵연료 운반용 실린더의 재사용을 위한 용기세척공장의 제염공정에 대한 성능을 평가하기 위하여 Na2CO3 + H2O2 혼합용액의 조합을 약간 달리한 2회의 시험을 실행하였다. 각 시험은 모두 일련의 5 단계에 걸쳐 실시되었다. 우라늄 제염의 주 화학종은 Na4UO2(CO3)3 로 식별되었다. 그리고 첫 단계에서의 세척액은 물이었으며, 이 단계에서 50% 이상의 우라늄이 제염되었다. 그 이후로는 단계가 더해 갈수록 우라늄의 제염양은 지수함수적으로 감소하는 경향을 나타내었으며, 화학양론적으로 제거된 우라늄에 비하여 투여된 Na2CO3 의 양은 과다함을 나타내었다. 이러한 결과들에 의하면, 공정최적화를 통하여 Na2CO3 의 투여량 감축, 세척폐액의 감량, 제염단계 축소 등을 꾀할 수 있을 것으로 판단된다.

목차

Abstract
 요약
 I. 서론
 II. 실험
 III. 결과 및 토의
  가. 일차시험
  나. 이차시험
 VI. 결론
 참고문헌

저자정보

  • Kwan Sik Chun 전관식. (주)유이엔지
  • Sung Hyun Yoo 유성현. (주)유이엔지
  • Young June Cho 조영준. (주)유이엔지
  • Jang Pyo Hong 홍장표. (주)유이엔지
  • Wook Jin Han 한욱진. 한전원자력연료(주)
  • Beong Soon Choi 최병순. 한전원자력연료(주)
  • Pil Sang Kang 강필상. 한전원자력연료(주)
  • Suk Ju Cho 조석주. 한전원자력연료(주)

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.