A pilot-plant biofilter (1750 mm W × 2750 mm L × 2000 mm H) packed with polyurethane foam (20 mm W × 20 mm L × 20 mm H) was installed in an fine chemical plant emitting gas streams containing ethyl alcohol, ethyl acetate, and dichloromethane. The biofilter was successfully operated for 30 days under highly fluctuating incoming concentrations (maximum 3500 ppm) at a residence time of 36 and 60 sec. Both ethyl alcohol and ethyl acetate were removed more than 95%, but dichloromethane removal was less than 50%. Malodor was also removed more than 90% from 17 days after start up.

한국어

본 연구는 폴리우레탄 입방체 (20 mm W × 20 mm L ×20 mm H)를 담체로 사용하고 자동교반장치가 장착된 pilot-scale의 바이오필터 (1750 mm W × 2750 mm L ×2000 mm H)를 정밀화학공정 현장에 설치하여 30일간 막힘 현상 등 제반 문제없이 성공적으로 가동하였다. 정밀화학공정에서 발생하는 가스에 함유된 ethyl alcohol, ethyl acetate 및 악취의 제거효율이 각각 95%, 95% 및 90%이었다. 반면 dichloromethane은 체류시간이 60초로 길어진 이 후에도 50% 이하에 머물렀다. 전체 데이터 중에서 유입공기내의 VOC 농도가 600 ppm이하인 조건인 경우만 따로 보았을 때 체류시간 36∼60초의 가스공급조건에서 ethyl alcohol은 운전초기부터 91%를 전후한 제거율을 보였고, 체류시간 60초에서는 고농도 유입조건에서도 95%를 상회하는 제거율을 보였다. Ethyl acetate 는 초기에는 제거효율이 낮았으나 체류시간이 60초로 길어졌을 때 95%전후의 높은 제거효율을 나타내었다. 악취 또한 90% 전후한 높은 제거율을 나타내었다. 유입가스의 농도가 심하게 변화하고 순간적으로 고농도 (최고 3500 ppm)로 유입됨에도 불구하고 매우 높은 제거율 (1038 g/m3․h)을 나타냄으로서 본 연구에서 사용한 pilot-scale 바이오 필터의 성능이 우수하다는 것을 입증하였다.

목차

Abstract
 서론
 재료 및 방법
  Pilot 바이오필터 설계 제작 및 제약공정과의 연결
  분석방법
 결과 및 고찰
  Total Hydrocarbon (THC)의 제거
  개별물질의 제거
  악취제거
  자동교반, pH조절 및 온도
 요약
 REFERENCES

저자정보

  • 류희욱 Hee Wook Ryu. 숭실대학교 환경화학공학과
  • 이태호 Tae Ho Lee. (주)바이오세인트
  • 박창호 Chang-Ho Park. 경희대학교 공과대학 화학공학과․그린에너지센터․산학협력기술연구원

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 원문제공기관과의 협약기간이 종료되어 열람이 제한될 수 있습니다.

      0개의 논문이 장바구니에 담겼습니다.