HFC-134a 냉매충전량의 변화에 따른 자동차용 에어컨 성능특성에 관한 연구

원문정보

A Study on the Performance of Automotive Air Conditioning System with variations of Charging HFC-134a Refrigerant

윤준규, 임종한, 김철수

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

HFC-134a is currently used as a refrigerant in automotive air conditioning system replacing the ozone depleting CFC-12 refrigerant. This paper was experimentally studied on the performance characteristics of an automotive air conditioning system with variations of charging refrigerant and compressor speed. An air conditioning system was composed of laminated type evaporator, parallel flow type condenser, vane rotary type compressor, externally equalized thermostatic expansion valve and receiver drier with specifications of Hyundai Sonata Ⅱ vehicle. And the automatic measuring system of air conditioner used KTE-1000BA developed by a KT ENG Co., Ltd.. of Korea. The optimum conditions which were tested as available parameters for better performance are indicated charging refrigerant 800 g and compressor speed 1700 rpm.

목차

Abstract
 1. 서 론
 2. 실험장치 및 방법
  2.1 실험장치 및 장치구성
  2.2 실험방법
 3. 실험결과 및 고찰
  3.1 에어컨 시스템의 열역학적 특성
  3.2 냉매충전량에 따른 열교환량과 성능 변화
  3.3 Mollier 선도상의 비교
 4. 결 론
 참 고 문 헌