earticle

논문검색

제3분야 : 구조

리브 보강 강관접합부의 내력평가에 관한 연구

원문정보

A Study on the Strength Evaluations of Tube Connection Stiffened with Rib Plate

김우범, 전범준, 이한나

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Current design practice of electric transmission tower is based on allowable stress design. Design strength of compression member of the electric transmission tower is determined by buckling strength of member itself without considering the joint strength. There is a possibility of joint failure prior to buckling of member. Therefore, in this study, joint strength is calculated
for various member force, and shape of joint and database of strength was established. These data was compared with the member strength obtained from previous research based on equivalent nonlinear analysis technique. Finally, practical evaluation and design method to distinguish failure mode in member of electric transmission tower is proposed.

목차

Abstract
 1. 서론
 2. 철탑의 극한 하중 도출
 3. 강관접합부의 내력 평가
 3.1 접합부 설계
  3.2 접합부의 유한요소해석
  3.3 리브로 보강된 강관 접합부의 실용설계식 제안
 4. 강관접합부 ENAT 반영
  4.1 가셋트 길이에 따른 영향
  4.2 리브 보강 각도에 따른 영향
 5. 결론
 참고문헌

저자정보

  • 김우범 Kim, Woo-Bum. 공주대학교 건축공학과 교수, 공학박사
  • 전범준 Jeon, Bum-Jun. 공주대학교 건축공학과 석사과정
  • 이한나 Lee, Han-Na. 공주대학교 건축공학과 학사과정

참고문헌

자료제공 : 네이버학술정보

    함께 이용한 논문

      ※ 기관로그인 시 무료 이용이 가능합니다.