earticle

논문검색

연구논문

Frontal Analysis와 Pulse Input Method를 이용한 Loxoprofen의 등온흡착식 결정

원문정보

Determination of Loxoprofen Adsorption Isotherms by Frontal Analysis and Pulse Input Method

이은, 박준섭, 김인호

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Frontal analysis (FA) and Pulsed input method (PIM) have been frequently utilized to measure isotherm of single solute , as well as non-competitive isotherms of two solutes in chromatography (1). FA and PIM were used in this study as complementary methods to measure adsorption isotherms of loxoprofen racemate in HPLC. Prior to FA and PIM experiments, measurements of loxoprofen solubility were made at exane/ethanol = 50/50, 80/20, 95/5 (v/v) with acetic acid (0.5%) for adjusting pH. The last composition (95/5) of hexane/ethanol allows us to separate loxoprofen racemate into two forms (retentate, extract). PIM and FA were used to determine the isotherms of re-and ex-loxoprofen.

한국어

본 실험의 목적은 frontal analysis (FA)와 pluse input method (PIM) 방법으로 흡착분리공정에 있어서 중요한 전단계의 하나인 등온흡착식을 결정하는데 있다. FA를 수행하기에 앞서 대상물질이었던 loxoprofen의 용해도를 측정하여 hexane / ethanol = 95 / 5일 때 시료의 농도를 0.2~3 mg/ml로
결정하고, pH 조정을 위한 acetic acid는 0.5%로 결정하였다.
이동상의 주성분인 hexane의 조성이 증가함에 따라 용해도는 감소하였지만 분리도는 증가하는 경향을 확인하였다.
이런 용해도와 분리도 사이의 trade-off 또한 흡착분리과정에서의 조작변수가 될 수 있음을 의미한다. FA로 구한 이성분계 등온흡착식은
C S, re =5.282C M, re/1+ 0.1412 C M, re+0.2139 C M, ex,
C S, ex =6.413 C M, ex/1+ 0.2139 C M, ex+0.1412 C M, re
로 결정하였고, PIM으로 구한 이성분계 등온흡착식은
C S, re =5.245C M, re/1+ 0.1667 C M, re+0.2054 C M, ex,
C S, ex =6.061 C M, ex/1+ 0.2054 C M, ex+0.1667 C M, re로 결정하였다.

목차

Abstract
 서론
 재료 및 방법
  재료 및 시약
  Frontal analysis
  Pulse input method
 결과 및 고찰
  Loxoprofen의 용해도 측정 및 초산과 농도결정
  Frontal analysis
  Pulse input method
 요약
 REFERENCES

저자정보

  • 이은 Eun Lee. 충남대학교 화학공학과
  • 박준섭 Joon Sub Park. 충남대학교 화학공학과
  • 김인호 In Ho Kim. 충남대학교 화학공학과

참고문헌

자료제공 : 네이버학술정보