원문정보
Removal of Gaseous Styrene using a Pilot-Scale Rotating Drum Biotrickling Filter
초록
영어
A new type of biofilter, a rotating drum biotrickling filter (RDBF), was developed and operated for the removal of styrene from industrial waste gas. The porous polyurethane foam sheet was used as a packing materials for the RDBF and a pure culture of Gram-positive bacterium Brevibacillus sp. SP1 was used as an inoculum. The reactor showed a short start-up period of 18 days, during which uniform biofilms were developed on the packing. During a steady operation at an incoming styrene concentration of 200 ppmv and a retention time of 0.5 min, a high and stable removal of styrene over 95% was observed. The maximum elimination capacity was estimated to be 125 g/m3․hr. The outstanding performance was attributed to an efficient gas-liquid mass transfer and the appropriate supply of nutrient solution to the biofilm microorganisms on the
packing by the rotation of the drum.
한국어
본 연구에서는 신 개념의 바이오필터 시스템인 RDBF를 이용하여 기상의 styrene을 제거하고자 하였다. 다양한 운전조건에서 시스템의 성능을 평가하고, 진공흡입을 통해 과다성장 미생물을 제어하고자 하였다. RDBF에서는 sheet 형태의 충진 담체를 사용하므로 영양원 및 공기의 균일한 공급이 가능하였고, 빠른 속도로 균일한 미생물 층을 담체 표면에 형성할 수 있었다. 또한 기-액 접촉면적을 증대 시켜 95% 이상의 안정적이고 높은 styrene 분해 효율과 125g/m3․h의 높은 제거 용량을 가질 수 있게 해주었다. 하지만 우수한 성능은 미생물의 과다성장에 따른 기공의 폐쇄현상 때문에 오래 지속되지 않았고 반응기의 성능과 안정성은 급속히 저하되었다. 이를 해결하기 위해 진공흡입을 통한 미생물 제거를 시도하였으나 제한적인 효과만을 확인하였다. 향후 RDBF 반응기의 상업화를 위해서는 보다 효율적인 미생물 제어 방법이 개발될 필요가 있다.
목차
서론
재료 및 방법
Pilot-scale 회전형 바이오필터
회전형 바이오필터의 운전조건 및 순서
미생물량 측정
진공흡입
분석방법
결과 및 고찰
RDBF의 운전
미생물 제거 실험
미생물량 정량
고찰
요약
REFERENCES