원문정보
Measurement of Biological Activity in Pilot Scale Dyeing Wastewater Process by Using Respirometer
초록
영어
Oxygen uptake rate (OUR) was used as an indicator of microbial activity. In this study OUR at dyeing wastewater in the pilot plant was monitored to examine biological activity. Correlation between inlet COD concentration and maximum OUR showed that maximum OUR was proportional to inlet COD concentration. Changes in the OUR values reflected the changing
waste load in the reactor. Consequently, OUR can be used to estimate biological activity of inlet COD concentration. This study showed that biodegradable COD at dyeing wastewater could be calculated from OUR and yield coefficient. Non-biodegradable COD was able to be calculated from a difference between initial COD concentration and biodegradable COD.
한국어
염색폐수내의 미생물 활성과 생분해 가능한 COD를 평가하여 효과적인 운전조건을 제시하고자 산소소모율을 측정하였다. 파일럿 플랜트 내로 유입되는 COD 농도 변화에 대한 최대산소소모율은 유입되는 농도가 높을수록 높은 값을 나타내어 COD와 최대산소소모율과의 상관관계를 통해 유입되는 COD농도에 미생물 활성을 예측할 수 있다. 또한 본 연구는 생물학적으로 분해 가능한 물질을 산소소모율 측정을 통한 소모된 산소의 양과 생산계수에 의해 계산하였으며, 생물학적 분해 가능한 COD 농도와 초기 COD 농도와의 차를 통해 난분해성 물질도 계산할 수 있었다.
목차
서론
재료 및 방법
사용균주
산소소모율 측정
분석방법
Biodegradable COD 계산
파일럿 플랜트
호흡율 측정기 (Respirometer)
결과 및 고찰
COD 농도 변화에 대한 미생물 활성도
Biodegradable COD 평가
요약
REFERENCES