An Investigation Analysis of Inflow and Infiltration into Combined Sewer System in Daejeon
초록
영어
In this study, inflow and infiltration of combined sewer system were analyzed at 4 sampling sites in Daejeon city during 1 month. Analyzing methods of Inflow and Infiltration(I/I) were water-use evaluation, maximum-minimum daily flow evaluation, maximum daily flow evaluation, and average-minimum daily flow evaluation. The investigation research results showed that average flow and ratio of I/I to total sewage were 599~6,422m3/d and 9.4~21.4% according to sampling sites. Average I/I production ratio per diameter and length of sewer according to sampling sites were evaluated 0.0123m3/d/mm-km(site of daedong), 0.0965m3/d/mm-km(site of gayang), 0.0178m3/d/mm-km(site of daejeon) and 0.0168m3/d/mm-km(site of yudeung), respectively.
목차
Ⅰ. 서 론
Ⅱ. 조사 방법
1. 조사 지점 선정
2. 조사기간 및 방법
Ⅲ. 조사 결과 및 분석
1. 하수의 유량 변동 특성
2. 하수의 일중 유량 변동 특성
3. 하수의 수질 분석결과
4. 침입수/유입수의 분석
Ⅳ. 결 론
참 고 문 헌