earticle

논문검색

연구논문

자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발

원문정보

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations

이종일

피인용수 : 0(자료제공 : 네이버학술정보)

초록

영어

Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the
immobilized XYO increased with the temperature (19.0 - 29.0oC) and sample injection volume (75-250 μL) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

목차

Abstract
 서론
 재료 및 방법
  시약
  효소 고정화
  XYO-FIA 시스템
 결과 및 고찰
  고정화 효소 XYO의 특성
  XYO-FIA 시스템의 성능 및 고찰
 결론
 REFERENCES

저자정보

  • 이종일 Jong Il Rhee. 전남대학교, 응용화학공학부, 생물공정기술연구실

참고문헌

자료제공 : 네이버학술정보