원문정보
Experimental study on the Joints for Light-weight Panel Filled with Mortar
모르타르 충전조립식경량판넬 접합부실험
초록
영어
The purpose of this study is to evaluate experimentally on the shear strength both of horizontal joint and vertical one for light-weight hybrid panel infilled with the light-weight foamed mortar. Horizontal joints consist of light-weight hybrid panel and composite slab. The experimental investigations are included the ultimate strength, yield strength, initial stiffness. As increasing the ratio of axial load, both the shear strength and the stiffness of the horizontal joint are enhanced as follows; 1.29 times in slip load, 1.36 times in ultimate strength, 1.61 times in initial stiffness. The friction factor of horizontal joints obtained by test result appears to be higher than 0.6, which is criterion value according to the Korean Standard. Shear tests for vertical joint are carried out both the shape of T-type and that of X-type being assembled with light-weight hybrid panel. As the test results, it is found that the density of light-weight formed mortar and the shape of joints are primely having an influence on both shear strength and failure mode for the vertical joint. It is obviously useful to making a specification for hybrid panel joint.
목차
1. 서 론
2. 실험체 제작
3. 소재시험
3.1 강재 인장강도 시험
3.2 콘크리트의 압축강도 시험
3.3 접합 나사
4. 가력 및 측정방법
5. 실험결과
5.1 수평접합부 실험체 거동
5.2 수직접합부 실험체의 거동
5.3 하중-변위 관계
6. 분석 및 고찰
6.1 수평접합부
6.2 수직접합부
7. 결 론
참 고 문 헌