초록 열기/닫기 버튼

The applications by using fiber laser have increased recently. However, due to high beam quality of fiber laser, it is inappropriate to apply the existing laser welding monitoring technology to the fiber laser welding as it is. On this study, thus, we analyzed emission signal with RMS and FFT for the in-process monitoring during fiber laser welding. 12mm-thick 304L stainless steel sheet was used in fiber laser welding and the result showed as follows: The intensity changes in RMS did not clarify the distinction between full penetration and partial penetration. However, as welding speed increases, specific frequency also increases in regards of frequency analysis by using FFT.